Master PDU Power Management Before Crisis Strikes
Every data centre operator dreads the 2AM alert—unexpected power failures that force emergency response calls and costly downtime. Without intelligent monitoring, you’re flying blind, reacting to crises instead of preventing them. The Raritan PX3 TS changes that equation with real-time visibility into your entire power infrastructure.
This advanced PDU power management solution delivers circuit-level monitoring with precise current, voltage, and power factor tracking across every outlet. Automated threshold alerts give you hours of warning before overload conditions occur, while the integrated console lets you manage power distribution remotely—eliminating the need for midnight site visits and keeping your critical systems running 24/7.
|
Enova Technologies
|
Power Infrastructure · Singapore
|
|
|
The 2AM Test
Every IT manager knows it.
The rack goes dark. The phone rings.
Someone has to be on-site.
|
|
Raritan PX3 TS — Alert Console
|
● LIVE
|
|
|
[ WARNING ] PDU-RACK12 › Circuit C2 › Outlet 14
Current load : 14.8A / Threshold: 15.0A (98.7%)
Voltage : 230V | Power factor: 0.97
Timestamp : 02:14:33 SGT
Load trend : +0.3A over last 12 minutes
Recommended action ›
Switch outlet remotely or shed load before circuit trips at ~02:18.
|
Alert delivered: 02:14:33. Estimated trip: 02:18:04. You have four minutes.
|
|
Most power incidents are not sudden. Load climbs. Nobody sees it. By the time the circuit trips, it is already 02:14 and the call is already on its way to you.
Raritan intelligent PDUs report outlet-level load continuously, to 0.1A resolution. You set the thresholds. The alert finds you before the trip does.
When you need to act, you switch the outlet remotely. No drive-in. No emergency callout. No explaining a 90-minute outage to management at 9AM.
|
|
|
|
What it actually does
|
|
⚡
|
Outlet-level metering, every second
Every outlet reports voltage, current, and power factor in real time. You see where load is building, not just where it failed. Measurement resolution: 0.1A per outlet.
|
|
|
🔔
|
Thresholds that alert before the trip
Set a warning threshold per outlet or per circuit. At 80%, the alert is already with you. At 90%, you have time to act. At 100%, the circuit trips and you do not. Delivered via SNMP, email, or syslog.
|
|
|
↻
|
Remote outlet switching, from anywhere
Reboot a hung server. Cycle a stuck switch. Shed load from a specific outlet. From any browser, or from Sunbird DCIM if you want a single pane of glass. No hands-on-site required.
|
|
|
|
|
One IP address. Up to 32 PDUs.
Raritan’s daisy-chain architecture lets you monitor an entire row of racks from a single network connection. Fewer management ports to provision. Cleaner topology. Outlet-level visibility across every unit in the chain.
|
|
|
We deploy Raritan PDUs across data centres in Singapore. We know which models suit which rack configurations, how to size the circuits, and how to integrate monitoring into Sunbird DCIM so the data is useful from day one, not six months later.
If you are managing power by exception, this changes that.
|
|
See what your racks look like right now.
We’ll walk you through a live Raritan demo. No commitment required.
|
|